grounding a Super

General discussion area for tube amps.

Moderators: pompeiisneaks, Colossal

Post Reply
User avatar
angelodp
Posts: 2157
Joined: Tue Jan 15, 2008 2:45 am
Location: L.A.

grounding a Super

Post by angelodp »

Friends does this look correct. I have graphically re-worked things. I will knot the new cord and new strain releif, I will put the ground wire to a tranny bolt.

[IMG:576:432]http://i260.photobucket.com/albums/ii9/ ... d_wire.jpg[/img]
Last edited by angelodp on Thu Jun 19, 2008 9:42 pm, edited 1 time in total.
User avatar
dartanion
Posts: 1562
Joined: Fri Mar 23, 2007 9:02 pm
Location: San Jose, CA
Contact:

Re: grounding a Super

Post by dartanion »

Get rid of the polarity switch, death cap, etc. Insert the new 3 conductor cord and hook the hot to the fuse, neutral to the PT tap, and ground to it's own chassis ground point.
Eardrums!!! We don't need no stinkin' eardrums!
User avatar
angelodp
Posts: 2157
Joined: Tue Jan 15, 2008 2:45 am
Location: L.A.

hot to fuse

Post by angelodp »

i think thats what i have show. Does it matter if the hot goes to the fuse tip or body??

ange
morcey2
Posts: 132
Joined: Mon May 12, 2008 5:31 pm

Re: hot to fuse

Post by morcey2 »

angelodp wrote:i think thats what i have show. Does it matter if the hot goes to the fuse tip or body??

ange
Hot should always go to the back of the fuse. That way, you don't have a live, uncovered piece of metal at the front when the fuse is pulled out.

Matt
User avatar
angelodp
Posts: 2157
Joined: Tue Jan 15, 2008 2:45 am
Location: L.A.

ok changed it

Post by angelodp »

I now have the hot to the back of the fuse and switch to the front. This should be good to go?

ange
User avatar
angelodp
Posts: 2157
Joined: Tue Jan 15, 2008 2:45 am
Location: L.A.

New grounding done

Post by angelodp »

Ok here it is. Am I ok with this. The neutral is spliced to the tranny black wire. The Hot is on the back of the fuse an ground is on a lug.

[IMG:1536:1152]http://i260.photobucket.com/albums/ii9/ ... G_1296.jpg[/img]
Firestorm
Posts: 3033
Joined: Fri Jan 25, 2008 7:34 pm
Location: Connecticut

Re: grounding a Super

Post by Firestorm »

Looks perfect to me.

EDIT: One thing: you should probably swap the wires on the fuse holder so the hot is at the far end. Otherwise, when you remove the fuse, you risk touching the hot supply.
User avatar
angelodp
Posts: 2157
Joined: Tue Jan 15, 2008 2:45 am
Location: L.A.

switched the wires

Post by angelodp »

Ok its done, thanks for the input. i did switch the wires on the fuse... damn dislexia gets me sometimes. But man she sings sweet now. Hum way down with the new grounded plug. sweeeeet.

cheers Ange