Just got my ceriatone trainwreck express clone. I want to change the tubes from 6v6 to el34's.
What should the bias voltage be for the 6v6 and what bias voltage for the el34.
Whats the best way to set the bias with my multimeter and which scale do i set the multimeter.
Hope someone can help.
Ben
Trainwreck clone biasing
Moderators: pompeiisneaks, Colossal
-
v00d00blues79
- Posts: 345
- Joined: Sun Mar 06, 2005 3:41 am
- Contact:
Re: Trainwreck clone biasing
Well... I biased mine by setting the trim-pot to where i got -30v on Pin 5 of the output tube. I run mine with both EL34's and 6V6's and this will work for both.
Thanks,
Andy
Thanks,
Andy
Re: Trainwreck clone biasing
Same here. Thats the way Ken does it! I still checked to make sure I was within safe ranges. The tubes are run a little hot! 
You do not have the required permissions to view the files attached to this post.
-
v00d00blues79
- Posts: 345
- Joined: Sun Mar 06, 2005 3:41 am
- Contact:
Re: Trainwreck clone biasing
I run some NOS RCA 6V6's in mine and it runs pretty good with'em.
Andy
Andy
-
populartsl
- Posts: 35
- Joined: Wed Oct 04, 2006 5:48 pm
- Location: UK
Re: Trainwreck clone biasing
Cheers guys
Ben
Ben
Re: Trainwreck clone biasing
now I'm getting confused. I read in the TW pages that KF biases his amps so that there is -30 V at the grids, so far so good. But my Express clone was made with Toneslut transformers, etc, by me, it's a different amp although I've tried hard to follow the known design, and I'm biasing it to hit the typical 70% idle dissipation and the negative voltage at the grid winds up at about -32 V plus change to reach that dissipation level.
So did KF intend to run the power tubes hotter than normal and that's why he prescribes the -30 bias? I had been assuming that he tweaked the amps to hit the common 70% dissipation but maybe that wasn't his aim and I've missed the point.
Any comments? What are your amps showing as idle plate dissipation with -30 V bias voltage?
So did KF intend to run the power tubes hotter than normal and that's why he prescribes the -30 bias? I had been assuming that he tweaked the amps to hit the common 70% dissipation but maybe that wasn't his aim and I've missed the point.
Any comments? What are your amps showing as idle plate dissipation with -30 V bias voltage?