The filament CT can probably be left for now.MGW wrote:Where would you ground the filament CT...Currently is shares a ground with the preamp cap can. Also, the B+ CT is grounded on a 50v zener bolted to the chassis.
Heater hum will be 60 Hz and you have to sort out your hash first.
Since you're using both a can and zener this precludes some of the more effective grounding schemes, as suggetsted by tubelectron in point #2.
The output section's cathodes, filter cap (and the bias system) should be tied as close as possible to the negative of the zener so as little (or no) current flows through the chassis.
If you can't connect a lug under the diode's chassis mounting get it as near as possible.
Merlin has as good as any reference to grounding:
http://valvewizard2.webs.com/Grounding.pdf
http://www.freewebs.com/valvewizard2/Grounding.html
reddog